Zoll AED Plus Defibrillator

AED Plus Automated External Defibrillator
AED Plus Automated External Defibrillator
Zoll AED PLUS AED Plus Automated External Defibrillator
  • Share
$1,699.00

$1699.00



By: Zoll
  • Zoll AED Plus Includes:
  • Zoll AED Plus Unit
  • Unique one piece Zoll Padz electrode
  • 10 type 123A Batteries
  • Prep Accessory Kit: razor, scissors, face shield, gloves, towelette
  • PASS (Passive Airway Support System) Cover
  • Soft carry case
  • Interactive In-Service Program CD
  • RescueNet Code Review Software download
  • Online Step-by-Step guided training
AED Plus Automated External Defibrillator
  • Provides real time analysis for performing shocks and high quality CPR
  • Graphical Operator Interface
  • The ZOLL AED Plus can defibrillate children up to eight years of age, using the pedipadz II electrodes
  • One-piece Electrode Pad System for fast and accurate placement, easy to apply
  • Analyzes heart rhythm and informs the rescuer if the rhythm is shockable or non-shockable
  • Delivers defibrillation treatment to victims of cardiac arrest who exhibit shockable ECG rhythms
  • Sequenced LED array gives fast communication of specific rescuer actions needed at the correct time
  • Voice prompts and graphics guide the rescuer regarding what to do and when to do it during a cardiac emergency - such as calling for help or giving CPR to the patient
  • Monitors the depth and rate of chest compressions during CPR and provides voice prompts
  • Notifies user of good compressions that are at least 2 inches deep and at a rate of 100 per minute
  • Notifies users if compressions are inadequate and when to push harder and/or faster
  • Meets the FDA's guidelines for requiring that chest compressions be at least 2 inches deep
  • Audible beeps encourage rescuers to provide CPR compressions at 100 CPM (requires Zoll CPR-D Padz)
  • Performs periodic self test to ensure its continual readiness
  • Upload data from the defibrillator to a PC to store events or print event reports
  • Unit cover functions as a Passive Airway Support System (PASS)
  • Resists dust and water
  • Proudly made in the USA
Zoll AED Plus Display
  • Shows prompt messages, advisory messages, elapsed time , shock count, chest compression graph
  • Configurable to display ECG
Zoll AED Plus Includes
  • Zoll AED Plus Unit
  • Unique one piece Zoll Padz electrode
  • 10 type 123A Batteries
  • Prep Accessory Kit: razor, scissors, face shield, gloves, towelette
  • PASS (Passive Airway Support System) Cover
  • Soft carry case
  • Interactive In-Service Program CD
  • RescueNet Code Review Software download
  • Online Step-by-Step guided training
More Details

Zoll AED Plus, the first and only full-rescue automated external defibrillator (AED) supports the full Chain of Survival by supporting effective CPR. The fact is, only half of cardiac arrest victims need a shock. The other half require high-quality cardiopulmonary resuscitation (CPR).

Other AEDs that do not help you perform CPR are really only working half the time. The Zoll AED Plus Defibrillator helps you all the time. ZOLL believes AEDs should not just deliver a shock. They should also help the rescuer provide high-quality cardiopulmonary resuscitation (CPR). The Zoll AED Plus is the only AED equipped with Real CPR Help to help you perform proper compressions at the correct rate and depth. The Zoll Automatic External Defibrillator supports the complete chain of survival by providing support for ALL victims of sudden cardiac arrest, even those for which no shock is advised.

The Zoll AED Plus provides Real CPR help, a tool that is able to actually see what you are doing and provide feedback to help you do it well, giving rescuers the confidence they need. Audio and visual prompts help make the rescue process easier than any other AED. From checking responsiveness, summoning help, and doing an "ABC" assessment (Airway, Breathing, Circulation) to CPR and defibrillation, the Zoll AED Plus helps guide the rescuer through the entire effort to save victims. The cover for the Electronic Defibrillator can be used to perform the Head Tilt-Chin Lift maneuver by placing the AED on the floor, below the patient's neck. The Portable Defribillator resists dirt and water.

Zoll offers a complete line of accessories to complement and restock the AED Plus. Wall mounting options include a simple bracket style, flush and recessed locking cabinets, and cabinet with alarm capability. Replacement padz for the adult and child size are available, as are training simulators and training padz. Signage for indicating Zoll AED Plus location can be purchased in two styles. Computer interface adapters for RS-232 and USB allows for uploading of information from the AED. And for portability, the hard-sided pelican cases can accommodate the AED and accessories.

Zoll AED Plus Defibrillators are proudly made in the USA.

Charge Time Less than 10 sec with new batteries
CPR Metronome Rate: Variable 60 to 100 CPM
Depth: 0.5" to 3" (1.3 to 7.8 cm)
Defibrillator Charge Hold Time 30 sec
Display Format: Optional LCD with Moving Bar
Size: 2.6 x 1.3" (6.6 x 3.3 cm)
Viewing Time: 2.6 seconds
Display Sweep Speed: 1"/sec (25 mm/sec)
Electrodes (CPR-D padz) Shelf Life: 5 years
Conductive Gel: Polymer Hydrogel
Conductive Element: Tin
Packaging: Multilayer foil laminate pouch
Impedance Class: Low
Cable Length: 36 in (91 cm)
Energy Selection Automatic pre-programmed selection (120J, 150J, 200J)
Patient Impedence Measurement Range 0 to 300 ohms
Power User Replaceable Batteries 10 Type 123A Photo Flash lithium manganese dioxide batteries
Weight 6.7 lbs (3.1 kg)
7 Year Warranty

The manufacturer warrants that this product is free from defects in material and workmanship. Repair, replacement or purchase price will be issued for any product which is found defective under the terms of this warranty.

Open, Used or Expired / Non Returnable

This product may be returned within 30 days of purchase provided the product packaging is unopened and product is unused. If item is found defective by the manufacturer, an exchange or refund will be offered.

Restock Fee

If returned, this product's manufacturer may charge a restocking fee of 15%.

To avoid factory restock fees, please consult with a QuickMedical sales associate to insure the product meets your needs. On site demos or factory approved trial and evaluations can be arranged, and may reduce or eliminate restocking fees.

What is Sudden Cardiac Arrest?

Sudden cardiac arrest means that the heart unexpectedly and abruptly quits beating. This is usually caused by an abnormal heart rhythm called ventricular fibrillation.

Is Sudden Cardiac Arrest the same as a heart attack?

No. A heart attack is a condition in which the blood supply to the heart muscle is suddenly blocked, resulting in the death of the heart muscle. Heart attack victims usually (but not always) experience chest pain and usually remain conscious. Heart attacks are serious and sometimes will lead to sudden cardiac arrest. However, sudden cardiac arrest may occur independently from a heart attack and without warning signs. Sudden cardiac arrest results in death if not treated immediately.

Who is at risk for Sudden Cardiac Arrest?

While the average age of sudden cardiac arrest victims is about 65, sudden cardiac arrest is unpredictable and can strike anyone, anywhere, anytime.

What is ventricular fibrillation?

Ventricular Fibrillation (VF) is an abnormal heart rhythm often seen in sudden cardiac arrest. This rhythm is caused by an abnormal and very fast electrical activity in the heart. VF is chaotic and unorganized; the heart just quivers and cannot effectively pump blood. VF will be short lived and deteriorate to asystole (a flat line) if not treated promptly.

How is ventricular fibrillation treated?

The only effective treatment for VF is an electrical shock called defibrillation. Defibrillation is an electrical current applied to the chest. The electrical current passes through the heart with the goal of stopping the VF and giving an opportunity for the heart's normal electrical system to take control. This current helps the heart reorganize the electrical activity so it can pump blood again. An automated external defibrillator (AED) can defibrillate the heart.

What does AED stand for?

AED stands for Automated External Defibrillator

What is an AED?

An AED is a device used to administer an electric shock through the chest wall to the heart. Built-in computer access the patient's heart rhythm, judge whether defibrillation is needed and then administer the shock. Audible and/or visual prompts guide the user through the process.

How does an AED work?

A microprocessor inside the defibrillator interprets (analyzes) the victim's heart rhythm through adhesive electrodes. The computer analyzes the heart rhythm and advises the operator whether a shock is needed. AED's advise a shock only for ventricular fibrillation and fast ventricular tachycardia. The electric current is delivered through the victim's chest wall through adhesive electrode pads.

Why are AED's important?

AED's strengthen the chain of survival. They can restore a normal heart rhythm in sudden cardiac arrest victims. Also, new portable models allow more people to respond to a medical emergency where defibrillation is required. After sudden cardiac arrest, chances of survival decreases by 7-10 percent each minute that passes without defibrillation. AED's save lives!

What if I mistakenly apply the AED to someone who fainted but still has a pulse, which I couldn't feel?

The AED is designed not to advise a shock for a patient with a non-shockable rhythm. It would be very difficult to harm a patient even in such circumstances.

What if I forget the steps for using the AED?

The steps for shocking a patient in cardiac arrest are simple and straightforward. The AED Plus provides the visual and audio prompts required for the entire resuscitation process. The most difficult part is recognizing the need for defibrillation.

What if I can't hear the voice prompts of the AED?

Look for the visual text prompts on the AED screen.

Should I do CPR first or apply the AED?

Do CPR only until the AED arrives. Apply the electrodes to the patient's bare chest and follow the voice prompts and messages of the AED. It will tell you when to resume CPR. CPR is a holding action until the heart is defibrillated.

If defibrillation is so important, why should I do CPR?

CPR provides some circulation of oxygen rich blood to the victim's heart and brain. This circulation delays both brain death and the death of heart muscle. CPR buys some time until the AED can arrive and also makes the heart more likely to respond to defibrillation.

Do I need to remove the defibrillator pads before doing chest compressions?

No. The pads remain on throughout the resuscitation and until the patient is transferred to advanced care providers such as the paramedics. If the pads are in their correct locations on the passenger's chest, they will not interfere with proper hand placement or compressions. When doing compressions, make sure the cable is not under your hands.

How much of the patient's clothing needs to be removed to carry out defibrillation?

The chest should be exposed to allow placement of the disposable defibrillation electrodes. A women's bra should be removed. Clothes may need to be cut off to facilitate early defibrillation.

After I have successfully defibrillated the patient and have return of a pulse, do I keep the AED on the patient?

Yes, even after a patient has been successfully defibrillated, he/she is at risk of developing ventricular fibrillation again. The AED will continually monitor the victim for the return of VF. If VF is suspected, the device will automatically begin to analyze patient after 1 minute of CPR is complete. The AED should be left on until emergency personnel assume responsibility for the patient. The defibrillation pads (electrodes) are disposable.

What if the victim regains a pulse but is not breathing or is breathing slowly?

Give rescue breaths at a rate of 1 every 5 seconds or 12 per minute.

If the patient is breathing and regains a pulse should the victim be placed back in a seat?

No, leave the patient on the floor; monitor pulse, breathing and blood pressure closely. Place the patient in the "rescue" or side position, keep them warm, administer oxygen, and continue to monitor closely.

Do all physicians and nurses know how to defibrillate?

Not all physicians and nurses know how to defibrillate, or they may not be familiar with the type of defibrillator you are using. Once you have been trained, continue to use it. Medical personnel may be needed to administer drugs, and give other advanced medical care.

Who is using AED's today?

Flight attendants, Firefighters, Cruise ship personnel, Police Officers, Health club employees, Security guards, EMT's, Lifeguards, Golf Pros, Students, Physicians, Nursing Homes, Residential Homes, Restaurant personnel and Corporate emergency response teams.

I placed the AED on a patient who had a cardiac arrest and the machine always prompted "No Shock Advised. Even with CPR the passenger did not survive. Why didn't the AED shock this victim?

Although VF is the most common rhythm in cardiac arrest it is not the only one. The AED will only shock VF. There are other heart rhythms associated with cardiac arrest that are not treated with defibrillation "shocks". A "No Shock Advised" message doesn't mean the victim's rhythm is back to normal. This is why a pulse check must always be done after a "No Shock Advised" prompt.

I shocked a woman in cardiac arrest 3 times within minutes after she collapsed. I heard later that she did not survive. Did I do something wrong?

Unfortunately, because of other underlying medical or heart problems, not all victims of cardiac arrest who are in ventricular fibrillation (VF) will survive even if defibrillation is done promptly and correctly

What if I don't perform all the steps of CPR and defibrillation perfectly?

A cardiac arrest is a high stress situation. Even experienced health care providers do not do everything perfectly. In a cardiac arrest, performing CPR, even imperfectly, and using a defibrillator can only help the patient.

Why is it so important to be sure that the defibrillation electrodes are firmly adhered to a clean, dry chest?

Successful defibrillation requires electricity to flow from one electrode to the other through the chest. If the electrodes are not firmly adhered and there is sweat or another conductive material between the electrodes, the electricity will be more likely to flow across the chest rather than through it. This will result in ineffective defibrillation and an increased chance of sparks and fire. (The main reason for removing therapeutic oxygen from the immediate vicinity of the victim.)

Is it okay to place the electrodes directly on a hairy chest?

Electrodes must come in direct contact with the skin. If the chest hair is so excessive as to prevent good adhesion of the electrode, the hair must be removed quickly.

What if I have a child victim?

Follow your protocols regarding the lower age or size limits for children. The American Heart Association recommends no one under 8 years old receive defibrillation with an automated external defibrillator.

What if I'm not certain whether or not I need to apply the defibrillator?

Remember this rule: only put the unit on someone you would do CPR on--unresponsive not breathing and no pulse.

Do patients "jump" when a shock is delivered?

Most will "jump" slightly although not to the extent seen on many television shows.

Should I use the AED if the passenger has a pacemaker or is pregnant?

Yes, never withhold AED use in a person in cardiac arrest (unresponsive, not breathing, no pulse).

Can I defibrillate on a wet surface?

Yes, as long as the usual safety rules are observed. Be sure the victim's chest is wiped dry. Keep the defibrillation electrodes away from a damp or conductive surface. Clear the victim and defibrillate as usual.

Can I defibrillate on or near a metal surface?

Yes, as long as the usual safety rules are observed. Keep the defibrillation electrodes away from contact with the conductive surface. Clear the victim and defibrillate as usual. Be sure not to allow anyone to touch the passenger when the shock is delivered.

Can I be sued using the defibrillator?

To date there has never been a case where someone was held liable for using an AED, but as you know, anyone can be sued. Likewise, most states have passed "Good Samaritan" legislation protecting the lay rescuer from lawsuits.

Can I accidentally shock another rescuer or myself?

AEDs are extremely safe when used properly. The electric shock is programmed to go from one pad to another through the victim's chest. Basic precautions, such a verbally warning others to stand clear and visually checking the area before and during the shock, will virtually ensure the safety of rescuers.

What if the patient has a medication patch on or EKG electrodes on the chest where I want to place the defibrillation pads?

Never place AED electrode pads directly on top of medication patches, such as nitroglycerin, or EKG patches. Patches should always be removed and the skin wiped dry before placing defibrillator pads on the skin.

What's the difference between the AEDs and the defibrillators that are shown on TV?

The defibrillators often shown on TV are called "manual defibrillators." A manual defibrillator is not "automated" the defibrillator does not interpret the need for defibrillation. Trained medical personnel interpret the heart's rhythms and make the decision whether to shock the patient or not. The shock can be delivered by the use of paddles or defibrillation pads.

Will I hurt the patient by using the AED?

When used on persons who are unresponsive, not breathing, and have no detectable pulse, the AED is extremely safe. The AED makes shock delivery decisions based upon the patient's heart rhythm, and will not allow a shock to be delivered if not needed. The machine will not let you shock a non-shockable rhythm. If the patient meets the criteria; unresponsive, not breathing, no pulse they are essentially "dead". "Deader", is just not a word in the dictionary.

What's public access to defibrillation?

Public access to defibrillation (PAD) means making AEDs available in public and/or private places where large numbers of people gather or people who are at high risk for heart attacks live.

What is Hands-Only CPR?

Hands-Only CPR is CPR without mouth-to-mouth breaths. It is recommended for use by people who see an adult suddenly collapse in the out-of-hospital setting. It consists of two steps:

1. Call 911 (or send someone to do that).

2. Begin providing high-quality chest compressions by pushing hard and fast in the center of the chest with minimal interruptions.

See Zoll Hands On CPR FAQ in More Info tab for more Frequently Asked Questions about Hands-Only CPR

Accessories

Lithium Battery 3 V
10 per Pack
$75.00
Special Order
Wall Mounting Bracket
$65.00
In Stock
Semi-Recessed Cabinet with Alarm
  • 20 gauge CR steel tub
$319.00
Factory Direct
Recessed Cabinet with Alarm
  • 20 gauge CR steel tub
$319.00
Factory Direct
Standard Wall Cabinet with Alarm
  • 20 gauge CR steel tub
$199.00
Factory Direct
CPR-D Padz (AED Pads)
  • Moist towelette
$169.00
Factory Direct
Pedi Padz II for AED Plus
$95.00
In Stock
AED Wall Sign
$11.00
Factory Direct
AED Sign, 3 Dimensional
$14.00
In Stock
RS-232 IRDA Adapter
$105.00
Factory Direct
USB IRDA Adapter
$105.00
Factory Direct
Surface Wall Mounting Cabinet with Alarm
  • 20 gauge CR steel tub
$319.00
Factory Direct
Pelican Case Small - Fits AED Plus Only
$199.00
Factory Direct
Pelican Case Large - Fits AED Plus, CPR-D padz, pedi padz II and a sleeve of batteries
$219.00
Factory Direct
AED Soft-Sided Case
1 Each
  • Features pockets for storing an extra set of electrodes and a sleeve of batteries
$105.00
In Stock